Written and checked by Lewis Wiggins, Gas Safe registered engineer (no. 636275). Updated .
A boiler usually loses pressure because of a leak somewhere in the heating system, a faulty pressure relief valve or a failed expansion vessel. You can top up the pressure to around 1 to 1.5 bar using the filling loop, but if it keeps dropping you need a Gas Safe engineer to find and fix the cause.
What should the pressure be?
Most sealed heating systems should read around 1 to 1.5 bar when cold, rising a little when the heating is on. Check your boiler manual for the exact figure. Below about 0.5 bar many boilers will lock out to protect themselves.
Common causes of pressure loss
- A leak in the system: check around radiator valves, visible pipework and under the boiler for drips or staining.
- Recently bled radiators: bleeding lets water out, so the pressure drops and needs topping up.
- Pressure relief valve: a faulty valve can let water out through a small copper pipe outside.
- Expansion vessel: if it loses its charge, pressure swings up and down and water can be discharged.
How to top up the pressure
Most combi boilers have a filling loop underneath. With the boiler off and cool, open the valves slowly until the gauge reads about 1 to 1.5 bar, then close them fully. Your boiler manual will show the exact steps for your model.
When to call us
If you are topping up more than once every few months, there is a fault to fix. Repeatedly adding fresh water also brings in oxygen that can corrode your system. Request a repair or call Lewis on 07867 388453.